{"id":1268,"date":"2026-07-01T06:05:55","date_gmt":"2026-07-01T14:05:55","guid":{"rendered":"https:\/\/www.recolux-led.com\/knowledges\/parking-lot-led-lighting-design-pole-height-spacing-ies-rp20-standards-and-glare-control-guide-2026\/"},"modified":"2026-07-01T06:06:27","modified_gmt":"2026-07-01T14:06:27","slug":"parking-lot-led-lighting-design-pole-height-spacing-ies-rp20-standards-and-glare-control-guide-2026","status":"publish","type":"knowledges","link":"https:\/\/www.recolux-led.com\/ru\/knowledges\/parking-lot-led-lighting-design-pole-height-spacing-ies-rp20-standards-and-glare-control-guide-2026\/","title":{"rendered":"\u041f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0432\u0435\u0442\u043e\u0434\u0438\u043e\u0434\u043d\u043e\u0433\u043e \u043e\u0441\u0432\u0435\u0449\u0435\u043d\u0438\u044f \u043f\u0430\u0440\u043a\u043e\u0432\u043e\u043a: \u0432\u044b\u0441\u043e\u0442\u0430 \u043e\u043f\u043e\u0440, \u0440\u0430\u0441\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u043c\u0435\u0436\u0434\u0443 \u043d\u0438\u043c\u0438, \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b IES RP-20 \u0438 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u043f\u0440\u0435\u0434\u043e\u0442\u0432\u0440\u0430\u0449\u0435\u043d\u0438\u044e \u043e\u0441\u043b\u0435\u043f\u043b\u0435\u043d\u0438\u044f (2026)"},"content":{"rendered":"<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528.webp\" alt=\"Parking Lot LED Lighting Design Guide\" class=\"wp-image-1266\" srcset=\"https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528.webp 1200w, https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528-18x10.webp 18w, https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528-600x338.webp 600w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Why Parking Lot Lighting Deserves Its Own Design Playbook<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A parking lot is the first and last impression a visitor has of your building. Too dim, and customers feel unsafe. Too bright, and you&#8217;re wasting energy and creating light pollution complaints from neighbors. The sweet spot is a designed system that meets <strong>IES RP-20<\/strong> standards, controls glare, and cuts energy costs by 50\u201370% compared to legacy HID fixtures.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This guide covers the engineering decisions that actually matter: pole height versus spacing ratios, when to use Type III versus Type V distribution, how to calculate the number of fixtures you actually need, and glare control strategies that keep drivers from seeing stars when they pull in at night.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>IES RP-20 Standards: The Baseline You Can&#8217;t Ignore<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The Illuminating Engineering Society&#8217;s <strong>RP-20-14<\/strong> standard defines recommended illuminance levels for parking facilities. These aren&#8217;t legally mandated everywhere, but they are the benchmark that insurers, code officials, and professional designers use to evaluate whether your lighting is adequate.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Area Type<\/th><th>Average Illuminance (lux)<\/th><th>Uniformity Ratio (Min\/Avg)<\/th><th>\u041f\u0440\u0438\u043c\u0435\u0447\u0430\u043d\u0438\u044f<\/th><\/tr><\/thead><tbody><tr><td>Entrance \/ Drive aisles<\/td><td>20\u201330 lx<\/td><td>\u2265 0.25<\/td><td>Higher traffic, prioritize uniformity<\/td><\/tr><tr><td>General parking stalls<\/td><td>10\u201320 lx<\/td><td>\u2265 0.20<\/td><td>Minimum 5 lx at any point<\/td><\/tr><tr><td>Pedestrian walkways<\/td><td>50\u2013100 lx<\/td><td>\u2265 0.30<\/td><td>Security-focused areas<\/td><\/tr><tr><td>Building perimeter \/ exits<\/td><td>100+ lx<\/td><td>\u2265 0.30<\/td><td>Surveillance camera requirements<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u041e\u0434\u043d\u043e\u0440\u043e\u0434\u043d\u043e\u0441\u0442\u044c<\/strong> matters more than peak brightness. A parking lot with 200 lx in one spot and 2 lx five meters away creates deep shadows where security cameras can&#8217;t see \u2014 and where people feel uneasy. Aim for a minimum-to-average ratio of at least 0.20, and 0.30 for pedestrian areas.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Pole Height and Spacing: The Geometry That Determines Everything<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The single biggest decision in parking lot lighting design is pole height. It affects spacing, uniformity, glare, and even how the installation looks from neighboring properties.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Recommended Pole Heights by Application<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Pole Height<\/th><th>Typical Application<\/th><th>Recommended Spacing<\/th><th>Fixture Wattage<\/th><\/tr><\/thead><tbody><tr><td>4\u20136 m (15\u201320 ft)<\/td><td>Small retail, strip malls<\/td><td>15\u201325 m<\/td><td>30\u201360 W LED<\/td><\/tr><tr><td>8\u201310 m (25\u201330 ft)<\/td><td>Standard commercial lots<\/td><td>25\u201335 m<\/td><td>60\u2013150 W LED<\/td><\/tr><tr><td>12\u201315 m (40\u201350 ft)<\/td><td>Large surface lots, municipal<\/td><td>35\u201350 m<\/td><td>150\u2013300 W LED<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u0421\u0430\u0439\u0442 <strong>spacing-to-mounting-height ratio<\/strong> is the rule of thumb designers use. For parking lots, a ratio of <strong>3:1 to 5:1<\/strong> (spacing divided by pole height) typically delivers acceptable uniformity. Go beyond 6:1 and you&#8217;ll get dark spots between poles that no amount of wattage can fix.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Single-Head vs. Multi-Head Poles<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A 10 m pole with 4 heads (directed north, south, east, west) covers roughly the same area as four 6 m single-head poles \u2014 but with one foundation, one wiring run, and a cleaner visual profile. For large lots, high-mast multi-head poles are almost always the better economic choice. The tradeoff is that a single failure affects a larger area, so reliability matters more.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Photometric Distribution Types: Type III, IV, and V Explained<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">LED parking luminaires are categorized by their distribution pattern. Picking the wrong type is the #1 reason parking lots have dark corners that never get fixed, no matter how many fixtures are added.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Type III<\/strong> \u2014 Asymmetric, throws light forward in a wide rectangle. Ideal for perimeter poles along the edge of a lot, or for roadway-adjacent lighting. Most common choice for parking lot perimeter rows.<\/li>\n<li><strong>Type IV<\/strong> \u2014 Asymmetric, narrower forward throw. Best for building wall packs and canopies where light needs to project outward from a linear row.<\/li>\n<li><strong>Type V<\/strong> \u2014 Symmetric, omnidirectional. The go-to for interior poles in the middle of a large lot. Distributes light evenly in all directions.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Mixing distribution types is normal. A typical design uses Type V for interior poles, Type III for perimeter poles, and Type IV for building-mounted fixtures along the facade.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Glare Control: Why Drivers Hate Your Parking Lot<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Glare is the leading cause of complaints about LED parking lot lighting. The issue isn&#8217;t brightness \u2014 it&#8217;s <em>contrast<\/em> \u0438 <em>optical control<\/em>. A bare LED chip at 6000K looks like a miniature sun to a driver transitioning from darkness. The solution is <strong>cutoff optics<\/strong> \u0438 <strong>color temperature management<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Full Cutoff (BUG Ratings)<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">ADA and IESNA classify luminaires by their Backlight-Uplight-Glare (BUG) ratings. For parking lots near roadways or residential areas, look for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Backlight (B)<\/strong> \u2014 B2 or lower if the fixture is near a property line<\/li>\n<li><strong>Uplight (U)<\/strong> \u2014 U0 or U1 for dark-sky compliance (no light above 90\u00b0)<\/li>\n<li><strong>Glare (G)<\/strong> \u2014 G2 or lower for areas where drivers look toward the fixture<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Full-cutoff optics use a combination of baffles, shields, and precision-refracted lenses to put light on the ground where it belongs, not in drivers&#8217; eyes or toward the sky.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Color Temperature and CRI for Parking Applications<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The 5000K-only mindset is fading. For parking lots, <strong>4000K<\/strong> is increasingly the recommended choice. It provides excellent visibility and perceived brightness while producing less harsh glare than 5000K. Some municipalities now restrict new installations to 3000K or 4000K for dark-sky compliance.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>CCT<\/th><th>\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0435<\/th><th>Dark-Sky Compliance<\/th><th>Typical Use Case<\/th><\/tr><\/thead><tbody><tr><td>3000K<\/td><td>Residential-adjacent lots<\/td><td>Excellent<\/td><td>Hotels, apartment complexes<\/td><\/tr><tr><td>4000K<\/td><td>General commercial<\/td><td>Good<\/td><td>Retail, office parks<\/td><\/tr><tr><td>5000K<\/td><td>Industrial, municipal<\/td><td>Poor (restricted in some cities)<\/td><td>Large surface lots, logistics yards<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Energy Efficiency and Controls<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Parking lot lighting runs 11 hours a day, 365 days a year. It&#8217;s one of the highest-ROI places to deploy controls:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Dusk-to-Dawn Photocell<\/strong> \u2014 Basic, reliable, saves 5\u201310% by tracking actual sunset\/sunrise.<\/li>\n<li><strong>Bi-level Dimming<\/strong> \u2014 Runs at 100% until 11 PM, then drops to 50% for the remaining hours. Saves 30\u201340% with negligible impact on perceived safety.<\/li>\n<li><strong>Motion-Activated Zones<\/strong> \u2014 PIR or microwave sensors trigger 100% output when a vehicle or pedestrian enters a zone, then dim back after 5 minutes of inactivity. Requires wireless control system (DALI, Zigbee, or proprietary).<\/li>\n<li><strong>Smart City Integration<\/strong> \u2014 NEMA 7-pin photocell sockets allow adding networked lighting controllers (NLCs) for remote monitoring, dimming schedules, and energy metering.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Retrofitting from HID to LED: What Actually Changes<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Most parking lot retrofits replace 250W\u2013400W metal halide or HPS fixtures with 60W\u2013150W LED equivalents. The wattage reduction is real, but there are three retrofit pitfalls to avoid:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Optical mismatch<\/strong> \u2014 HID fixtures have symmetric, diffuse distribution. LED retrofits with narrow beam angles create bright spots directly under the fixture and dark perimeters. Always request a photometric layout before buying.<\/li>\n<li><strong>Color shift complaints<\/strong> \u2014 HPS is warm (1900K). Jumping to 5000K LED feels harsh to regular users. Consider 4000K or even 3000K for smoothed transition.<\/li>\n<li><strong>Pole condition<\/strong> \u2014 If the existing poles are 15+ years old, a retrofit is the time to inspect and potentially replace them. LED fixtures last 50,000\u2013100,000 hours; don&#8217;t mount them on poles that might fail in 5 years.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Dark-Sky Compliance and Municipal Regulations<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Many cities now have outdoor lighting ordinances that restrict fixture type, color temperature, and uplight. Before finalizing a design, check:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Maximum allowed CCT (3000K in cities like Tucson, AZ; 4000K in many others)<\/li>\n<li>Full-cutoff requirement (no light above 90\u00b0 horizontal)<\/li>\n<li>Maximum zoning-intensity limits (expressed in average lux or footcandles)<\/li>\n<li>IDR (Illuminating Design Resolution) compliance for coastal or astronomy-sensitive areas<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Using full-cutoff LED fixtures at 4000K or lower is the simplest way to ensure compliance with most municipal codes while still delivering excellent visibility.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Quick Specification Checklist<\/strong><\/h2>\n\n\n\n<li><strong>\u041e\u0441\u0432\u0435\u0449\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/strong>: 10\u201320 lx average for stalls, 20\u201330 lx for drive aisles<\/li>\n<li><strong>\u041e\u0434\u043d\u043e\u0440\u043e\u0434\u043d\u043e\u0441\u0442\u044c<\/strong>: Min\/Avg \u2265 0.20 (stalls), \u2265 0.30 (pedestrian areas)<\/li>\n<li><strong>Pole height<\/strong>: 8\u201310 m for standard commercial; 12\u201315 m for large lots<\/li>\n<li><strong>CCT<\/strong>: 4000K recommended; 3000K for residential-adjacent<\/li>\n<li><strong>BUG rating<\/strong>: U0 or U1 (no uplight), G2 or lower (glare control)<\/li>\n<li><strong>Controls<\/strong>: Photocell standard; bi-level dimming strongly recommended<\/li>\n<li><strong>Surge protection<\/strong>: 10 kV minimum for areas with frequent electrical storms<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Complete guide to parking lot LED lighting design. Covers pole height, fixture spacing, IES RP-20 standards, glare control, and energy-efficient retrofit strategies for commercial and municipal parking areas.<\/p>","protected":false},"featured_media":1266,"parent":0,"menu_order":0,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"led-knowledge":[212],"class_list":["post-1268","knowledges","type-knowledges","status-publish","format-standard","has-post-thumbnail","hentry","led-knowledge-parking-lot-area-lighting"],"acf":[],"spectra_custom_meta":{"_uagb_previous_block_counts":["a:90:{s:21:\"uagb\/advanced-heading\";i:0;s:15:\"uagb\/blockquote\";i:0;s:12:\"uagb\/buttons\";i:0;s:18:\"uagb\/buttons-child\";i:0;s:19:\"uagb\/call-to-action\";i:0;s:15:\"uagb\/cf7-styler\";i:0;s:11:\"uagb\/column\";i:0;s:12:\"uagb\/columns\";i:0;s:14:\"uagb\/container\";i:0;s:21:\"uagb\/content-timeline\";i:0;s:27:\"uagb\/content-timeline-child\";i:0;s:14:\"uagb\/countdown\";i:0;s:12:\"uagb\/counter\";i:0;s:8:\"uagb\/faq\";i:0;s:14:\"uagb\/faq-child\";i:0;s:10:\"uagb\/forms\";i:0;s:17:\"uagb\/forms-accept\";i:0;s:19:\"uagb\/forms-checkbox\";i:0;s:15:\"uagb\/forms-date\";i:0;s:16:\"uagb\/forms-email\";i:0;s:17:\"uagb\/forms-hidden\";i:0;s:15:\"uagb\/forms-name\";i:0;s:16:\"uagb\/forms-phone\";i:0;s:16:\"uagb\/forms-radio\";i:0;s:17:\"uagb\/forms-select\";i:0;s:19:\"uagb\/forms-textarea\";i:0;s:17:\"uagb\/forms-toggle\";i:0;s:14:\"uagb\/forms-url\";i:0;s:14:\"uagb\/gf-styler\";i:0;s:15:\"uagb\/google-map\";i:0;s:11:\"uagb\/how-to\";i:0;s:16:\"uagb\/how-to-step\";i:0;s:9:\"uagb\/icon\";i:0;s:14:\"uagb\/icon-list\";i:0;s:20:\"uagb\/icon-list-child\";i:0;s:10:\"uagb\/image\";i:0;s:18:\"uagb\/image-gallery\";i:0;s:13:\"uagb\/info-box\";i:0;s:18:\"uagb\/inline-notice\";i:0;s:11:\"uagb\/lottie\";i:0;s:21:\"uagb\/marketing-button\";i:0;s:10:\"uagb\/modal\";i:0;s:18:\"uagb\/popup-builder\";i:0;s:16:\"uagb\/post-button\";i:0;s:18:\"uagb\/post-carousel\";i:0;s:17:\"uagb\/post-excerpt\";i:0;s:14:\"uagb\/post-grid\";i:0;s:15:\"uagb\/post-image\";i:0;s:17:\"uagb\/post-masonry\";i:0;s:14:\"uagb\/post-meta\";i:0;s:18:\"uagb\/post-taxonomy\";i:0;s:18:\"uagb\/post-timeline\";i:0;s:15:\"uagb\/post-title\";i:0;s:20:\"uagb\/restaurant-menu\";i:0;s:26:\"uagb\/restaurant-menu-child\";i:0;s:11:\"uagb\/review\";i:0;s:12:\"uagb\/section\";i:0;s:14:\"uagb\/separator\";i:0;s:11:\"uagb\/slider\";i:0;s:17:\"uagb\/slider-child\";i:0;s:17:\"uagb\/social-share\";i:0;s:23:\"uagb\/social-share-child\";i:0;s:16:\"uagb\/star-rating\";i:0;s:23:\"uagb\/sure-cart-checkout\";i:0;s:22:\"uagb\/sure-cart-product\";i:0;s:15:\"uagb\/sure-forms\";i:0;s:22:\"uagb\/table-of-contents\";i:0;s:9:\"uagb\/tabs\";i:0;s:15:\"uagb\/tabs-child\";i:0;s:18:\"uagb\/taxonomy-list\";i:0;s:9:\"uagb\/team\";i:0;s:16:\"uagb\/testimonial\";i:0;s:14:\"uagb\/wp-search\";i:0;s:19:\"uagb\/instagram-feed\";i:0;s:10:\"uagb\/login\";i:0;s:17:\"uagb\/loop-builder\";i:0;s:18:\"uagb\/loop-category\";i:0;s:20:\"uagb\/loop-pagination\";i:0;s:15:\"uagb\/loop-reset\";i:0;s:16:\"uagb\/loop-search\";i:0;s:14:\"uagb\/loop-sort\";i:0;s:17:\"uagb\/loop-wrapper\";i:0;s:13:\"uagb\/register\";i:0;s:19:\"uagb\/register-email\";i:0;s:24:\"uagb\/register-first-name\";i:0;s:23:\"uagb\/register-last-name\";i:0;s:22:\"uagb\/register-password\";i:0;s:30:\"uagb\/register-reenter-password\";i:0;s:19:\"uagb\/register-terms\";i:0;s:22:\"uagb\/register-username\";i:0;}"],"rank_math_internal_links_processed":["1"],"_thumbnail_id":["1266"],"_uag_css_file_name":["uag-css-1268.css"]},"uagb_featured_image_src":{"full":["https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528.webp",1200,675,false],"thumbnail":["https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528.webp",128,72,false],"medium":["https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528.webp",1200,675,false],"medium_large":["https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528.webp",768,432,false],"large":["https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528.webp",1200,675,false],"1536x1536":["https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528.webp",1200,675,false],"2048x2048":["https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528.webp",1200,675,false],"trp-custom-language-flag":["https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528-18x10.webp",18,10,true],"woocommerce_thumbnail":["https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528-300x300.webp",300,300,true],"woocommerce_single":["https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528-600x338.webp",600,338,true],"woocommerce_gallery_thumbnail":["https:\/\/www.recolux-led.com\/wp-content\/uploads\/2026\/07\/recolux-img-260528-100x100.webp",100,100,true]},"uagb_author_info":{"display_name":"Recolux","author_link":"https:\/\/www.recolux-led.com\/ru\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"Complete guide to parking lot LED lighting design. Covers pole height, fixture spacing, IES RP-20 standards, glare control, and energy-efficient retrofit strategies for commercial and municipal parking areas.","_links":{"self":[{"href":"https:\/\/www.recolux-led.com\/ru\/wp-json\/wp\/v2\/knowledges\/1268","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.recolux-led.com\/ru\/wp-json\/wp\/v2\/knowledges"}],"about":[{"href":"https:\/\/www.recolux-led.com\/ru\/wp-json\/wp\/v2\/types\/knowledges"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.recolux-led.com\/ru\/wp-json\/wp\/v2\/media\/1266"}],"wp:attachment":[{"href":"https:\/\/www.recolux-led.com\/ru\/wp-json\/wp\/v2\/media?parent=1268"}],"wp:term":[{"taxonomy":"led-knowledge","embeddable":true,"href":"https:\/\/www.recolux-led.com\/ru\/wp-json\/wp\/v2\/led-knowledge?post=1268"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}